General purpose flexible heater

                                       ELECTRICALLY HEATED SILICONE BLANKETS

Silicone Rubber Heaters are used where an even application of heat over relatively large areas is desired. 

Silicone Rubber Heaters utilize a heating element which consists of fine gauge, stranded and stress relieved wire, Nickel Chrome Iron or Nickel Copper alloys are used throughout for durable and reliable service.

A Fullchance Silicone Heater may be permanently installed using adhesives applied by the customer.

Temporary or removable placement for purposes of maintenance, container cleaning, etc. is facilitated by the addition of hooks, eyelets, or Velcro® closure attached to the blanket for this purpose.

UL RATED - Fullchance Silicone Rubber Heating Blankets are qualified under The Underwriters Laboratories Component Recognition File Number 69443 for applications not exceeding 392°F.
Specifications

Temperature Rating  

400°F (204 °C) maximum operating

Size/Shape Limitations

Maximum width of 48", no maximum length

Thickness  

~0.06" (Single-Ply) ~0.12" (Dual-Ply)

Voltage  

Any AC or DC

Wattage  

 Customer specified (Normal maximum of 5 Watts per square inch)

Power Lead wires  

Silicone Rubber, SJ Power Cord, or Teflon insulated stranded wire

Attachment  

Hooks, Lacing Eyelets, or Velcro® Closure.

Ordering Information BLANKETCHART.gif
Useful Information * Drawing with pertinent dimensions * - or - A description of item to be heated including open or unheated areas, special port or access requirements. * Voltage and Wattage (if known). * Temperature control method desired including addition of a thermocouple or other temperature sensors in heater.

FULLCHANCE FIBERGLASS BLANKET HEATERS AND JACKETS
CONSTRUCTION: Heating Element is a fine gauge, multiple stranded, stress relieved wire insulated with fiberglass yarn and secured to the heating face. Element construction of up to 150 feet of stranded wire per square foot of surface eliminates hot spots and insures fast heat up time and long service life. Heating Face and Cover are fiberglass fabric woven of “itch-proof” Beta glass high temperature yarns. Thermal Insulation is a fiberglass felted wool. One inch thick is standard. Seam Closure provided by nickel plated lacing hoods is standard. Eyelets, Velcro ™ tape, and lacing ties are also available. Power Leadwires are a high temperature fiberglass insulated nickel plated copper. fiber.jpg
Specifications

Temperature Rating
 750°F (400° C) maximum
Size/Shape  Limitations
 None
Thickness
 1" Standard, 1/4" minimum
Voltage
 Customer specified
Wattage
Customer specified (Normal maximum of 8 Watts per square inch)
Power Leadwires
Fiberglass insulated Nickel clad Copper, Silicone Rubber, or Teflon insulated stranded wire.
Attachment
 Hooks, eyelets, or Velcro tape.

Ordering Information

  • Drawing or description of item to be covered including open or unheated areas, special port or access requirements, etc.
  • Voltage and Wattage (if known).
  • Temperature control method desired including addition of a thermocouple or other temperature sensors in heater.